Description
Compression Load Cells
The SCCSC-C3 load cell is available in 7 capacities from 5t to 50t. A perfect selection for all tank, hopper and silo work where long life and stability are pre-requisites for the many and varied requirements of industry.
It is an excellent selection for many hostile environments due to its welded heavy-duty stainless steel construction and wide range of weighing capacities, coupled with a quality IP68 protection rating and inbuilt surge protection.
The special mounting accessories make the SCCSC-C3 an ideal choice for the professional weighing installer, using our simple top & bottom mount Type 3, side adjustable restraining mount Type 1 or the unique side & uplift restraining mount Type 2 all provide for a simple ‘set and forget’ installation.
Three standard mountings are available to be sure you gain the maximum performance by using one of the special Scale Calibration Pty Ltd designed and manufactured mounting kits.
The SCCSC-C3 has Scale Calibration Pty Ltd.comprehensive warranty and is supplied individually packed with a detailed accuracy certificate traceable by serial number.
Specification
SPECIFICATIONS | |||
Nominal Capacity Signal output at capacity Linearity Error Non-Repeatability Combined Error Hysteresis Creep (30 mins) Zero Balance Temperature Effect On Span/10ºC Temperature Effect on Zero/10ºC Compensated Temperature Range Operating Temperature Range Storage Temperature Range Sealing Excitation +ve Signal +ve |
5t ~ 50t 2mV/V ± 0.5% < 0.020% FSO < 0.020% FSO < 0.020% FSO < 0.020% FSO < 0.016% FSO < 1.000% Capacity < 0.011% FSO < 0.015% Capacity -10 ~ 40° C -35 ~ 65° C -50 ~ 65°C IP68, 300hrs @ 1.5m RED GREEN |
Service Load Safe Load Ultimate Load Input Resistance Output Resistance Insulation Resistance (brd to grd) Excitation Voltage (Rec) Excitation Voltage (Max) Power Surge Arrestors Tilt (Max Transverse Displace) Cable Type |
100% of Rated Capacity 150% of Rated Capacity 300% of Rated Capacity 700Ω ± 7Ω Nominal 703Ω ± 4Ω Nominal > 5000 MΩ at 50V DC 5 ~ 12V AC/DC 18V AC/DC Fitted as standard 12mm 5mm, Screened, PUR Sheath Stainless Steel, welded BLACK |
DIMENSIONS | CAPACITIES | |
Model SCCSC-C3-5t SCCSC-C3-10t SCCSC-C3-20t SCCSC-C3-25t SCCSC-C3-30t SCCSC-C3-40t SCCSC-C3-50t |
Capacity 5t 10t 20t 25t 30t 40t 50t
|
Load Cell Dimensions (mm) |
||||
Capacity | A | B | C | Weight(kg) |
5t ~ 20t | 40.0 | 14.0 | 22.0 | 2.5 |
25t~30t | 40.0 | 14.0 | 22.0 | 3.0 |
40t~50t | 50.0 | 21.0 | 28.0 | 3.5 |
Features
Product Description
Description
Compression Load Cells
The SCCSC-C3 load cell is available in 7 capacities from 5t to 50t. A perfect selection for all tank, hopper and silo work where long life and stability are pre-requisites for the many and varied requirements of industry.
It is an excellent selection for many hostile environments due to its welded heavy-duty stainless steel construction and wide range of weighing capacities, coupled with a quality IP68 protection rating and inbuilt surge protection.
The special mounting accessories make the SCCSC-C3 an ideal choice for the professional weighing installer, using our simple top & bottom mount Type 3, side adjustable restraining mount Type 1 or the unique side & uplift restraining mount Type 2 all provide for a simple ‘set and forget’ installation.
Three standard mountings are available to be sure you gain the maximum performance by using one of the special Scale Calibration Pty Ltd designed and manufactured mounting kits.
The SCCSC-C3 has Scale Calibration Pty Ltd.comprehensive warranty and is supplied individually packed with a detailed accuracy certificate traceable by serial number.
Specification
SPECIFICATIONS | |||
Nominal Capacity Signal output at capacity Linearity Error Non-Repeatability Combined Error Hysteresis Creep (30 mins) Zero Balance Temperature Effect On Span/10ºC Temperature Effect on Zero/10ºC Compensated Temperature Range Operating Temperature Range Storage Temperature Range Sealing Excitation +ve Signal +ve |
5t ~ 50t 2mV/V ± 0.5% < 0.020% FSO < 0.020% FSO < 0.020% FSO < 0.020% FSO < 0.016% FSO < 1.000% Capacity < 0.011% FSO < 0.015% Capacity -10 ~ 40° C -35 ~ 65° C -50 ~ 65°C IP68, 300hrs @ 1.5m RED GREEN |
Service Load Safe Load Ultimate Load Input Resistance Output Resistance Insulation Resistance (brd to grd) Excitation Voltage (Rec) Excitation Voltage (Max) Power Surge Arrestors Tilt (Max Transverse Displace) Cable Type |
100% of Rated Capacity 150% of Rated Capacity 300% of Rated Capacity 700Ω ± 7Ω Nominal 703Ω ± 4Ω Nominal > 5000 MΩ at 50V DC 5 ~ 12V AC/DC 18V AC/DC Fitted as standard 12mm 5mm, Screened, PUR Sheath Stainless Steel, welded BLACK |
DIMENSIONS | CAPACITIES | |
Model SCCSC-C3-5t SCCSC-C3-10t SCCSC-C3-20t SCCSC-C3-25t SCCSC-C3-30t SCCSC-C3-40t SCCSC-C3-50t |
Capacity 5t 10t 20t 25t 30t 40t 50t
|
Load Cell Dimensions (mm) |
||||
Capacity | A | B | C | Weight(kg) |
5t ~ 20t | 40.0 | 14.0 | 22.0 | 2.5 |
25t~30t | 40.0 | 14.0 | 22.0 | 3.0 |
40t~50t | 50.0 | 21.0 | 28.0 | 3.5 |