SC9010WA Weighbridge Load cell Assembly

Description


The SC9010WA is designed for road and rail scales, the capacity ranges from 10t to 50t with a small footprint and a low profile. The design of the cell via its central loading through the ball free motion makes it less sensitive to side loads.
PT9010WA is constructed of alloy steel with all internal components protected by way of fully welded encapsulation which provides for an excellent protection level against the elements.

Specification

SPECIFICATIONS
Signal
output at capacity
Linearity Error
Non-Repeatability
Combined Error
Hysteresis
Creep/(30 mins.)
Zero Balance
Temperature Effect On Span/10ºC
Temperature Effect on Zero/10ºC
Compensated Temperature Range
Operating Temperature Range
Storage Temperature Range
Excitation +ve
Signal +ve
2±0.002
mV/V
< 0.017% FSO
< 0.020% FSO
< 0.020% FSO
< 0.020% FSO
< 0.020% FSO
< 1.5% Capacity
< 0.014% FSO
< 0.017% FSO
-10 ~ 40 C
-35 ~ 65 C
-50 ~ 85 C
RED
GREEN
Service
Load
Safe Load
Ultimate Load
Input Resistance
Output Resistance
Insulation Resistance
Excitation Voltage (Rec)
Excitation Voltage (Max)
Cable

Material
Sealing
Excitation -ve
Signal -ve
100%
Capacity
150% Capacity
300% Capacity
700Ω ± 37Ω
700Ω ± 7Ω
> 5000 MΩ  (@50 VDC)
5 ~ 12 V AC/DC
18 V AC/DC
12m
4 core shielded
Alloy Steel/Steel
IP68 welded sealed
BLACK
WHITE
DIMENSIONS CAPACITIES
SC9010WA Model
SC9010WA-10t
SC9010WA-20t
SC9010WA-25t
SC9010WA-30t
SC9010WA-40t
SC9010WA-50t
Capacity
10t
20t
25t
30t
40t
50t
Dimensions
(mm)
Capacity Order A B C D E F G H J K L Weight(kg)
10t 9010M010TWAXXX 80 125 30 50 88 11 18 195 100 135 240 14.2
20t 9010M020TWAXXX 80 125 30 76 88 11 18 225 100 135 240 16.1
25t 9010M025TWAXXX 80 125 30 76 88 11 18 225 100 135 240 16.1
30t 9010M030TWAXXX 80 125 30 76 88 11 18 225 100 135 240 16.1
40t 9010M040TWAXXX 80 125 30 76 88 11 18 225 100 135 240 16.1
50t 9010M050TWAXXX 124 160 40 82 98 11 21 261 124 160 340 24

Features

Product Description

Description


The SC9010WA is designed for road and rail scales, the capacity ranges from 10t to 50t with a small footprint and a low profile. The design of the cell via its central loading through the ball free motion makes it less sensitive to side loads.
PT9010WA is constructed of alloy steel with all internal components protected by way of fully welded encapsulation which provides for an excellent protection level against the elements.

Specification

SPECIFICATIONS
Signal
output at capacity
Linearity Error
Non-Repeatability
Combined Error
Hysteresis
Creep/(30 mins.)
Zero Balance
Temperature Effect On Span/10ºC
Temperature Effect on Zero/10ºC
Compensated Temperature Range
Operating Temperature Range
Storage Temperature Range
Excitation +ve
Signal +ve
2±0.002
mV/V
< 0.017% FSO
< 0.020% FSO
< 0.020% FSO
< 0.020% FSO
< 0.020% FSO
< 1.5% Capacity
< 0.014% FSO
< 0.017% FSO
-10 ~ 40 C
-35 ~ 65 C
-50 ~ 85 C
RED
GREEN
Service
Load
Safe Load
Ultimate Load
Input Resistance
Output Resistance
Insulation Resistance
Excitation Voltage (Rec)
Excitation Voltage (Max)
Cable

Material
Sealing
Excitation -ve
Signal -ve
100%
Capacity
150% Capacity
300% Capacity
700Ω ± 37Ω
700Ω ± 7Ω
> 5000 MΩ  (@50 VDC)
5 ~ 12 V AC/DC
18 V AC/DC
12m
4 core shielded
Alloy Steel/Steel
IP68 welded sealed
BLACK
WHITE
DIMENSIONS CAPACITIES
SC9010WA Model
SC9010WA-10t
SC9010WA-20t
SC9010WA-25t
SC9010WA-30t
SC9010WA-40t
SC9010WA-50t
Capacity
10t
20t
25t
30t
40t
50t
Dimensions
(mm)
Capacity Order A B C D E F G H J K L Weight(kg)
10t 9010M010TWAXXX 80 125 30 50 88 11 18 195 100 135 240 14.2
20t 9010M020TWAXXX 80 125 30 76 88 11 18 225 100 135 240 16.1
25t 9010M025TWAXXX 80 125 30 76 88 11 18 225 100 135 240 16.1
30t 9010M030TWAXXX 80 125 30 76 88 11 18 225 100 135 240 16.1
40t 9010M040TWAXXX 80 125 30 76 88 11 18 225 100 135 240 16.1
50t 9010M050TWAXXX 124 160 40 82 98 11 21 261 124 160 340 24

Features